CS (DO2 Configuration) Command
<AT Command: Serial Interfacing> CS Command
is used to modify the behavior of the CTS
 signal
such that it either provides RS-232 flow control,
enables RS-485 transmission / reception or deter-
mines RS-422 transmit enable. By default, CTS
 
provides RS-232 flow control. CS Parameter must
be adjusted for the modem to operate in RS-485/
422 environments.
CT (Time before Exit AT Command Mode) Parameter
<Non-AT Settable Parameter: AT Command Options> AT Command Mode can be exited manually
using CN (Exit AT Command Mode) Command or, after a given time of inactivity, the modem exits
AT Command Mode on its own and return to Idle Mode. CT Command sets the amount of time
before AT Command Mode is exited automatically. If no characters are received before this time
elapses, the modem will return to Idle Mode.
Parameter Range: 0x02 - 0xFFFF [x 100 ms]
# of bytes returned: 2
Default Parameter Value: 0xC8 (200d (20 decimal seconds))
DB (Receive Signal Strength) Command
<AT Command: Diagnostic> DB Parameter returns the receive signal strength (in decibels) of the
last received packet. This Parameter is useful in determining range characteristics of the XCite
Modules under various conditions.
AT Command: DB
Parameter Range: 0x25 - 0x6A [Read-only]
# of bytes returned: 1
DT (Destination Address) Command
<AT Command: Networking> DT Command is used to set the address of the XCite Radio Modem.
XCite Radio Modems use three network layers - the Vendor Identification Number (ATID), Chan-
nels (ATHP) and Destination Addresses (ATDT).
DT Command assigns an address to a radio modem that enables it to communicate only with radio
modems that have matching addresses. This is similar to interconnecting several PCs under a
common hub. All radio modems that share the same destination address can communicate freely
with each other. Radio Modems in the same network with a different destination address (than that
of the transmitter) will listen to all transmissions to stay synchronized, but will not send any of the
data out their serial ports.
AT Command: DT
Parameter Range: 0 - 0xFFFF
# of bytes returned: 2
Default Parameter Value: 0
Related Commands: ID (Modem ID), HP (Channel), MK (Address Mask)
AT Command: ATCS
Parameter Ranges: 0 - 4
Parameter
Configuration
0
Normal CTS
1
RS-485 enable (low)
2
high
3
RS-485 enable (high)
4
low
Default Parameter Value: 0
Number of bytes returned: 1
相关PDF资料
ZMN2400HPDB BOARD ROUTER DEV ZIGBEE 100MW
ZMN24HPDK-B KIT DEV W/ZIGBEE ZMN2400HP
ZNI1000TC IC TEMP SENSOR NI1000 SOT23-3
02110102-000 SNSR TILT RATIO 60DEG 500MA FLNG
1-5209285-2 FOPC BOA 12DB FC/UPC BP SM
2-1693560-0 BOA 20DB LC/UPC BB
517SS16 MAGNETIC SENSORS BIPOLAR ICS
5209597-9 BOA 9DB DW SC/APC
相关代理商/技术参数
XIB-U 功能描述:界面模块 USB interface board 24XStream 9XCite RoHS:否 制造商:4D Systems 产品:Serial Converters 通道/端口数量: 数据速率: 接口类型:USB, UART 工作电源电压:3.3 V, 5 V 最大工作温度:
XIC25040 制造商:XIC 功能描述:25040 24HR '6
XILINXPWR-079 功能描述:电源管理IC开发工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-080 功能描述:电源管理IC开发工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-081 功能描述:电源管理IC开发工具 Pwr Mgmt Eval Mod Xilinx RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-082 功能描述:电源管理IC开发工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-083 功能描述:电源管理IC开发工具 Pwr Mgmt Eval Mod Xilinx RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XIM15120-G-C2E 制造商:Thomas & Betts 功能描述:INCANDESCENT